This protocol is to ensure that an accurate 3-D model can be created. Review the following information before proceeding with the scanning process. If you have never worked with ProtoMED before or if you have any questions please contact a ProtoMED representative at 303-466-5610 prior to scanning the patient.
To download a copy of the Craniofacial-General scanning protocol, right click and save to your desktop.
|
Area |
FOV |
Pitch |
Slice Thickness |
*mA |
Time |
|
Mandible/Maxilla |
20 cm |
1.0 |
1 mm |
120-280 |
N/A |
|
Full Skull |
20 cm |
1.0 |
1 mm |
120-280 |
N/A |
*Maximize the mAs without overheating the tube.
The following is a list of CT scanners currently supported at ProtoMED. Please archive image data (not raw data) onto the appropriate media.
FOR BEST RESULTS, PRINT THIS TABLE FROM THE PROTOCOL DOWNLOAD
|
Scanner Brand |
Image Storage |
Scanner Type |
Media Type |
||||
|
Pioneer Optical Disk |
Maxoptix Optical Disk |
4mm DAT Tape |
8mm DAT Tape |
CD or PTF |
|||
|
Elscint |
Uncompressed |
CT Twin |
X |
||||
|
Exel 2400 |
X |
||||||
|
Twin Flash** |
X |
||||||
|
GE |
Compressed |
CT PACE |
X |
X |
X |
||
|
CT/i (DICOM Images) |
X |
X |
|||||
|
Hilight Advantage |
X |
x |
|||||
|
Hispeed Advantage |
X |
X |
X |
||||
|
Lightspeed Qx/i (DICOM Images) |
X |
X |
|||||
|
Prospeed |
X |
X |
X |
||||
|
Cytec |
X |
X |
X |
||||
|
Sigma (MR) |
X |
||||||
|
Hitachi |
Uncompressed |
Hitachi MRP 7000 |
X |
X |
|||
|
Hitachi W 950 |
X |
X |
|||||
|
Hitachi W 2000 |
X |
X |
|||||
|
Phillips |
Uncompressed |
Easy Vision |
X |
X |
|||
|
Tomoscan CX, CS/S, CX/Q |
X |
X |
|||||
|
Tomoscan LX, LX/C |
X |
X |
|||||
|
Tomomscan SR |
X |
X |
|||||
|
Tomoscan 60/TX, TX |
X |
X |
|||||
|
Picker |
Uncompressed |
MX Twin Helical (DICOM Images) |
X |
X |
|||
|
MX 8000 (DICOM Images) |
X |
X |
|||||
|
PQ 2000 |
X |
X |
|||||
|
PQ 5000 |
X |
X |
|||||
|
PQ 6000 |
X |
X |
|||||
|
Siemens |
Uncompressed |
Emotion Duo |
X |
X |
|||
|
Magnetom (MR) |
X |
X |
|||||
|
Somatom AR |
X |
X |
|||||
|
Somatom Balance |
X |
X |
|||||
|
Somatom DRH |
X |
X |
|||||
|
Somatom HiQ |
X |
X |
|||||
|
Somatom Plus |
X |
X |
|||||
|
Somatom Volume Zoom |
X |
X |
|||||
|
Toshiba |
Uncompressed |
IS&C Formatted |
X |
X |
|||
If you have a scanner not supported on this list, please call a ProtoMED representative at 303-466-5610 to discuss computability issues.
Siemens® is a registered trademark of Siemens AG. General Electric® is a registered trademark of General Electric Company. Picker® is a registered trademark of Picker International, Inc. Toshiba® is a registered trademark of Toshiba Corporation. Elscint® is a registered trademark of Elscint, Inc.