Craniofacial Scanning Protocol
This protocol is to ensure that an accurate 3-D model can be created. Review the following information before proceeding with the scanning process. If you have never worked with ProtoMED before or if you have any questions please contact a ProtoMED representative at 303-466-5610 prior to scanning the patient.
To download a copy of the Craniofacial-General scanning protocol, right click and save to your desktop.
PRE-SCAN PROCEDURE
- Remove any jewelry that is in the scan area.
- Stabilize the patient with sponges, tape and any other accessories that will not cause injury to the patient or affect the quality of the CT Scan.
- Note: It is extremely important that the patient does not move or swallow during the scanning process.
- Position the patient so that he/she lay supine.
SCANNING PARAMETERS HELICAL
|
Area
|
FOV
|
Pitch
|
Slice
Thickness |
*mA
|
Time
|
|
Mandible/Maxilla
|
20
cm
|
1.0
|
1
mm
|
120-280
|
N/A
|
|
Full
Skull
|
20
cm
|
1.0
|
1
mm
|
120-280
|
N/A
|
*Maximize the mAs without overheating the tube.
- Inform the patient that they should not move or swallow until the scan is complete.
- Inform the patient when the actual scanning process starts.
- Use the Standard Algorithm.
- Gantry Tilt must be set to 0.
- Use an appropriate FOV so the image fills the entire screen but be sure that the desired anatomy is visible.
- Label the CD or disk with scanner type, date of scan, patient name/number, physician name, facility name, CT technologist name, and CT technologist telephone number.
- Send the data to ProtoMED.
Scanners Supported
The following is a list of CT scanners currently supported at ProtoMED. Please archive image data (not raw data) onto the appropriate media.
FOR BEST RESULTS, PRINT THIS TABLE FROM THE PROTOCOL DOWNLOAD
|
Scanner
Brand
|
Image
Storage
|
Scanner
Type
|
Media
Type
|
||||
|
Pioneer
Optical Disk
|
Maxoptix
Optical Disk
|
4mm
DAT Tape
|
8mm
DAT Tape
|
CD
or PTF
|
|||
|
Elscint
|
Uncompressed
|
CT
Twin
|
X
|
||||
|
Exel
2400
|
X
|
||||||
|
Twin
Flash**
|
X
|
||||||
|
GE
|
Compressed
|
CT
PACE
|
X
|
X
|
X
|
||
|
CT/i
(DICOM Images)
|
X
|
X
|
|||||
|
Hilight
Advantage
|
X
|
x
|
|||||
|
Hispeed
Advantage
|
X
|
X
|
X
|
||||
|
Lightspeed
Qx/i (DICOM Images)
|
X
|
X
|
|||||
|
Prospeed
|
X
|
X
|
X
|
||||
|
Cytec
|
X
|
X
|
X
|
||||
|
Sigma
(MR)
|
X
|
||||||
|
Hitachi
|
Uncompressed
|
Hitachi
MRP 7000
|
X
|
X
|
|||
|
Hitachi
W 950
|
X
|
X
|
|||||
|
Hitachi
W 2000
|
X
|
X
|
|||||
|
Phillips
|
Uncompressed
|
Easy
Vision
|
X
|
X
|
|||
|
Tomoscan
CX, CS/S, CX/Q
|
X
|
X
|
|||||
|
Tomoscan
LX, LX/C
|
X
|
X
|
|||||
|
Tomomscan
SR
|
X
|
X
|
|||||
|
Tomoscan
60/TX, TX
|
X
|
X
|
|||||
|
Picker
|
Uncompressed
|
MX
Twin Helical (DICOM Images)
|
X
|
X
|
|||
|
MX
8000 (DICOM Images)
|
X
|
X
|
|||||
|
PQ
2000
|
X
|
X
|
|||||
|
PQ
5000
|
X
|
X
|
|||||
|
PQ
6000
|
X
|
X
|
|||||
|
Siemens
|
Uncompressed |
Emotion
Duo
|
X
|
X
|
|||
|
Magnetom
(MR)
|
X
|
X
|
|||||
|
Somatom
AR
|
X
|
X
|
|||||
|
Somatom
Balance
|
X
|
X
|
|||||
|
Somatom
DRH
|
X
|
X
|
|||||
|
Somatom
HiQ
|
X
|
X
|
|||||
|
Somatom
Plus
|
X
|
X
|
|||||
|
Somatom
Volume Zoom
|
X
|
X
|
|||||
|
Toshiba
|
Uncompressed
|
IS&C
Formatted
|
X
|
X
|
|||
If you have a scanner not supported on this list, please call a ProtoMED representative at 303-466-5610 to discuss computability issues.
Siemens® is a registered trademark of Siemens AG. General Electric® is a registered trademark of General Electric Company. Picker® is a registered trademark of Picker International, Inc. Toshiba® is a registered trademark of Toshiba Corporation. Elscint® is a registered trademark of Elscint, Inc.
PRODUCT
TECHNOLOGY | SURGICAL PLANNING
| CASE STUDIES
CUSTOMER
SERVICE | CONTACT | HOME
© 2002-2004 ProtoMED, Inc.